Mashiinka Sifaynta Biyaha ee Isku-dhafan ee Ultrapure ee Isticmaalka Kiliinikada ee Isticmaalka Dhexe ee Biyaha MK-JC

  • Description
  • sooc Technical

Tilmaamaha Nidaamka >

● Fully automatic operation, power-on self-test, raw water under-pressure protection, over-pressure/water full automatic Shutdown, real-time monitoring of tap water conductivity, pure water conductivity, EDI water resistance LCD liquid crystal display such as rate, product water resistivity, etc.

● Using Cortex-A8 processor 7-inch man-machine interface and microcomputer control, all Program real-time animation simulation display, with parameter modification and data storage and printing functions.

● Components adopt imported and domestic top brand accessories to make the system run more stably To ensure the quality of effluent water.

● Nidaamka oo shaqeynaya waqtiga wadarta ah iyo bandhigga waqtiga-dhabta ah, shaqada badalka waqtiga nidaamka Kara, badalka waqtiga mashiinka iyo isticmaalayaasha usbuuca si xor ah u deji.

● Digniinta cilladaysan ee nidaamka iyo shaqada digniinta beddelka ah ee la isticmaali karo, daaqadda bandhiggu waxay soo bandhigaysaa digniinta waqtiga dhabta ah ee macluumaadka booliiska.

● The system is fully automatic flushing design and internal circulation function, prolonging the service life of RO .

● Qaybaha waxay qaataan agabka summada ugu sareysa ee dibadda laga keeno iyo kuwa gudaha laga keeno si nidaamku si habsami leh ugu shaqeeyo Xasilloon si loo hubiyo tayada biyaha wasakhaysan.

● The system can upgrade the remote monitoring function, which can realize remote operation and animation simulation Real-time monitoring, sound-activated alarm, data printing and other functions.

● PLC , LCD touch screen, DCS , camera monitoring and other technologies to achieve Remote automatic display, operation and control. The computer records the operating parameters of the equipment, Print the report, which is convenient for analyzing the data correlation between the experimental water quality and the experimental results.


Influent water quality will affect the quality of pure water and the life of consumables, When the water TDS ≥ 500 ppm , it is recommended to use a pre-double softening device or a two-stage reverse osmosis process

Halbeegyada Technical

nooca Number MK - JC 300/500/1000L- RD , MK - JC 300/500 /1000L-2 RD , MK - JC 300/500/1000L-2 RDE
socodka habka Reverse osmosis + purification process / reverse osmosis + purification process + EDI / Two-stage reverse osmosis + purification process + EDI
Wax soo saarka biyaha 300/500/1000L/H
Tayada biyaha alaabta Grade I reverse osmosis conductivity ≤10 us / cm (25℃), Grade I reverse osmosis conductivity N/A, ≤5 us / cm (25°C), ED resistivity N/A, 10- 15 MQ / cm (25℃), Number of particles (0 . 22 um )<1/ ml ,

Shuruudaha System

Shuruudaha biyaha Biyaha qasabada ee dawlada hoose
Cadaadiska gudaha 0.2-0.4Mpa
shuruudaha korontada 380V/AC 50Hz
Heerka Guusha 2-5KW
heerkulka kharashka 5-45 ℃
Deegaanka Rakibaadda Hawo-qaadid, qoyaan-celin, ka-hortagga daxalka