XAALADAHA HOTELKA
Centrifuge Plasma Gel Centrifuge 12/24 Kooxaynta Dhiiga Aqoonsiga Seerological
| Codsiyada: | ●ABO blood type test test ●Rh blood group antigen test ●Irregular antibody screening ●Cross match |
●HDN detection ●Platelet antibody screening ●Platelet crossmatch |
| Max. Xawaare | 3500pm | |
| Max.RCF | 1554xg | |
| Max.Capacity | Kaararka 24 | |
| Rotors oo isku mid ah | Disk card rotors | |
| Display | LCD | |
| Number Model: | XK-12B | |
| Certification: | CE, ISO13485,ISO9001:2015 | |
| damaanad | 1 sano oo dammaanad ah mashiinka oo dhan, 3 sano oo dammaanad ah kombaresarada iyo 5 sano oo dammaanad ah matoorka. Qaybaha beddelka bilaashka ah iyo dhoofinta dammaanadda gudaheeda. | |
- Description
- Video
- sooc Technical
- Rotors iyo Agabka
- Advantage tartanka
Micro column gel technology is extensively employed in blood serology, routine serum detection, red blood cell washing, microcolumn gel immunoassay experiments, and other applications due to its standardized operation and sensitive testing capabilities. The XK-12B blood gel card desktop low-speed centrifuge with a 12/24 card rotor meets the standard operation requirements for batch processing. The system features microcomputer control and automatic imbalance detection technology, ensuring easy operation and precise detection results. This instrument is essential for experimental hematology in hospitals and blood banks.
Principle for Blood Gel Card(ID-Card) Centrifuge
The principle behind the Blood Gel Card Centrifuge is based on the microcolumn gel immunoreaction, specifically the red blood cell agglutination test, also known as microcolumn gel hemagglutination assay (MGHA). Within the microcolumn gel tube, the red blood cells and their corresponding antibodies combine to form a clump of red blood cells. Through low-speed centrifugation, the clot is positioned either on the surface or within the gel, while the red blood cells that are not bound to the antibody settle at the bottom of the tube (the tip of the tube bottom).
Faa'iidada
The advantages of Micro Column Gel Technology include its simplicity of operation, lack of washing and confirmation tests for negative results, which solves the problem of the Coombs test being difficult to routinely apply in clinical practice due to its complexity and time-consuming nature. It also promotes the incomplete antibody detection theory to become the clinical "gold standard". The system can process multiple specimens at once (12/24 cards), enabling the detection of a large number of clinical specimens. Additionally, it offers advantages such as accuracy, sensitivity, minimal specimen consumption, long-term storage of results, easy standardization, and safer operation.
Paternity Testing Method
The Paternity Testing Method involves the use of ABO blood type positive and negative type and RhD blood type test cards to detect human ABO and RhD antigens. The column agglutination method (microcolumn gel method) is a commonly used immunological method for blood group identification, in which red blood cell antigens and corresponding antibodies agglutinate in a microcolumn gel medium. This method is standardized and quantified, ensuring the accuracy of the results.
The following steps are involved in the process:
1.Blood sample collection (note: samples containing abnormally increased serum protein should be washed sufficiently before use).
2. Blood sample processing:
(i) Centrifuge the anticoagulated whole blood sample at 900~1000g centrifugal force for 5 minutes, the lower layer is the concentrated packed red blood cells with a concentration of about 80%. Carefully absorb the upper plasma in another test tube, which can be used directly in the experiment.
(ii) Dilute the packed red blood cells to be tested: Take 8-10μl packed red blood cells and add 1ml red blood cell diluent. The appearance should be a uniform light red with no flocs or blood clots. (iii) Dilute the red blood cells: Take 8-10μl packed red blood cells and add 1ml red blood cell diluent. The appearance should be a uniform light red with no flocs or blood clots.
3. Blood type card operation:
1) Mark the prepared micro-living gel reagent card.
2) Add the prepared red blood cell suspension to the first to fourth tubes respectively, and add the diluted inverted red blood cells to the fifth to sixth tubes.
3) Immediately centrifuge for 5 minutes (900rpm for 2 minutes, 1500rpm for 3 minutes) in a blood type card centrifuge, and take out the result of the naked eye judgment.
Design
● Microprocessor control with Brushless Motor. Accurate speed control.
● Easy operation. Colorful digital screen indicates all running parameters. Automatic lid -open alarm when the instrument is off.
● Professional programming design. No need for manual setting. Just run it.

Isticmaalaha saaxiibtinimo
● Si otomaatig ah u xidhid daboolka iyo haynta inta lagu jiro orodka rotor-ka.
● Nidaamka is-aqoonsiga oo leh qolal-xoog-sare leh-dahaar iyo ilaalin.
● Tignoolajiyada la aqoonsan yahay ee "Af-ka-bakhti", hawlgalka xawaaraha ugu sarreeya wuxuu ka yar yahay 50 decibels.
● Si toos ah u beddelka rpm/rcf.

Ammaanka
● Lagu soo saaray si waafaqsan xeerarka badbaadada caalamiga ah (tusaale IEC 61010).
● Nabdoonaanta daboolka korantada, albaabku ma furmi karo marka rotor-ku socdo mishiinkana ma shaqayn doono marka daboolku furmo oo uu soo baxo koodka khaladku.
● Siideynta degdega ah ee qufulka furka marka korontadu xumaato (aad bay faa'iido u leedahay goynta korontada ee lama filaanka ah).
● Ilaalinta badbaadada waxaa loo sameeyay xawaaraha dheeriga ah si loo hubiyo badbaadada mashiinka ninka.

| Qiyaasta xawaaraha (rpm) | 0-3500rpm la hagaajin karo | Buuq (dBA) | ≦50 dB(A) |
| Awoodda ugu badan (ml) | 24 cards | Aragti (mm) | 430*320*250mm(12 cards) 440*400*230mm(24 cards) |
| Kala duwanaanshaha RCF (xg) | 0-1554xg hagaajin karo | miisaanka Net | 13 KG (with 12 cards) 22KG (with 24 cards) |
| Power sahayda | AC220V,50HZ,5A,60W | ||
| No. | Shayga | Capacity | Xawaaraha wareega | Max.RCF | Time | note |
|
NO.1
|
Pre-centrifuge program group | Kaararka 12 | 3500r / min | 1232xg | 1 daqiiqo | Program group can be set for different blood type cards. |
|
NO.2
|
Test program group | Kaararka 12 | 900r / min | 81xg | 2 daqiiqo | |
| 1500r / min | 226xg | 3 daqiiqo | ||||
|
NO.1
|
Pre-centrifuge program group | Kaararka 24 | 3500r / min | 1554xg | 1 daqiiqo | |
|
NO.2
|
Test program group | Kaararka 24 | 800r / min | 81xg | 2 daqiiqo | |
| 1335r / min | 226xg | 3 daqiiqo | ||||
![]() | ||||||
1.Professional centrifuge saaraha, qiimaha tartanka.
2.ISO9001, ISO13485, CE, Shahaadada SFDA, dhammaan mishiinnada waxay maraan tijaabo tayo adag leh iyo baakado wanaagsan ka hor inta aan la qaadin.
Taageerada farsamada ee muddada-dheer iyo adeegga macaamiisha xirfadlaha ah ee 3.Wax kasta oo ka mid ah iibinta alaabta, bixinta iyo hawlgalka.Our tayo sare leh iyo kooxda adeegga khibrad leh oo ku siinaya heer gaar ah oo taageero ah iibsashadaada oo dhan.
4.Waxaan sidoo kale ku siin karnaa xalal gaar ah oo loogu talagalay shuruudaha gaarka ah ee macaamiisha.
5.Powered leh koox wax ku ool ah oo injineero ah oo ay taageerayaan sannado khibrad u leh goobahooda, shirkaddu waxay hubisaa mid kasta oo ka mid ah alaabooyinka ka tagaya qaybta wax soo saarka ilaa calaamadda dhammaan dhinacyada.

EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
VI
SQ
HU
MT
TH
TR
FA
AF
MS
GA
BE
AZ
KA
MN
KK
UZ