Qalabka Biyaha Sifaynta Mashiinka Biyaha ee aadka u saafiga ah ee Shaybaadhka ee Shaybaarka Caafimaadka

  • Description
  • sooc Technical

1. Application scope: ultrasonic cleaning, high performance liquid chromatography, atomic absorption, mass spectrometry analysis, TOC detection, ICP-MS, etc.

2. The water quality of the produced water is in line with GB-T6682-2008 analytical laboratory water standard level 1 water standard.

3. 3.2-inch LCD display, real-time display of operating status.

4. It can simultaneously display RO pure water conductivity, UP resistivity, temperature, time, tank water level, etc. online at the same time.

5. It can set the pre-treatment, reverse osmosis, pure water column, UV lamp and other consumables replacement time and consumables use the remaining time reminder function.

6. The system adopts double pump automatic operation and regular automatic circulation to ensure stable water quality.

7. The sterile water tank adopts sanitary injection molding, set air filter, stainless steel level sensor, submerged UV lamp, etc. to strictly control the breeding of bacteria in the water tank.

8. The shell of the consumables adopts a modular quick-plug design, which is convenient and quick to replace.

9. The system program controls automatic flushing, automatic flushing when starting up and when the water is full, prolonging the service life of RO.

10. The microfilter at the end of the system and the integrated fine treatment make the water quality more stable and reliable, and the plug-in design of the accessories makes it easier to replace the accessories.

11. The system has low operating power, low noise, strong anti-interference, and a variety of accessories can be used for various complex water quality.

12. When the turbidity of tap water is relatively high, it is recommended to add a pre-automatic filter device, which can realize automatic positive and negative flushing functions. (additional configuration)

>The quality of influent water will affect the quality of pure water and the life of the filter column. When the influent TDS is greater than or equal to 200ppm, it is recommended to add a pre-softening device or adopt a two-stage reverse osmosis process

>Pretreatment; integrated PP cotton (PP); integrated activated carbon (DUF); reverse osmosis (RO); ion exchange (DI); ultraviolet lamp sterilization and digestion (UV); ultrafiltration (UF); terminal filter (TF)

1. Halbeegyada aasaasiga ah

1. Model: MK-SYHI- 4 0L (Other Volume Option: 10L, 20L, 60L)

2. Process flow: PP+DUF+RO+DI+TF

3. Water inlet requirements: municipal tap water (pressure 0.2-0.4Mpa temperature 5-45℃ TDS value ≤ 200us/cm)

4. Water production capacity: 4 0L/H

5. Power supplypower: 220V AC 45W

6. Water intake flow rate: ≥1.2L/min

7. Size : 530 * 450 * 930mm

8. Water storage device: 60 liters sterile water tank

9. Two or more water inlets for pure water and ultrapure water

2. Cabirrada farsamada

1. Pure water conductivity ≤10us/cm(25℃)

2. The resistivity of ultrapure water is 18.2MΩ/cm (25°C)

3. Total organic carbon (TOC)<10ppb

4. The number of microorganisms<1 cfu/ml

5. The number of particles (≤0.22um)<1/ml

6. Absorbance (254nm, 1cm optical path) ≤ 0.001

7. Compatible silicon (calculated as SiO2) ≤ 0.01mg

3. Configuration list

magaca model or specification tirada
jiifku 40 litir 1 set
Preprocessing module 20 inches 1 set
Bamka Diaphragm 75G 1 set
Dib-u-noqoshada nidaamka osmosis 40L /h 1 set
Sterile water tank 60 litir 1
Bamka wareegga 02V 1 set
Dareemaha heerka dareeraha marxalado badan 1 set
Terminal filter 0.22um 1 ul
Filterka hawada 0.22um 1 ul
Purification column module 20 inches sets 2
Water inlet solenoid valve
1
Flush solenoid valve
1
UV lamp module 285 1 set
RO water intake solenoid valve
1
UP water intake solenoid valve
1
High voltage controller
1 set
Low voltage controller
1 set
Korontada beddeleysa
1 set
Resistivity meter
1 set
Fittings
1 batch
Microcomputer processor
1
Nidaamka xakamaynta korantada
1 set
Control Panel
1 set
WEYDIISASHADA